(of course, most of you know that) the mgn is a wire (current carrying, i believe) that runs parallel to the 3 phase wires on power lines, usually below them. Connect the transformer primary according to the wiring diagram on the nameplate.
It is the one with the center bushing (x2) tied to the neutral.

Pole mounted transformer wiring diagram. Pole mounted transformers are electric utility distribution transformers that are mounted on an electrical service pole (wood or concrete) and are usually at the level of the overhead cables. These highly reliable transformers are available in a wide variety of ratings and accessory combinations. These transformers are designed for the application conditions normally encountered on.
4000 volts rms factory and field wiring Call for hot line stirrup separately: When that is the case, transformers will be installed at the pole location closest to the building with the greatest load.
Anything below those is comm. Energize the unit and check the secondary voltage to ensure it is proper for the load. The transformer in the middle is the lighting transformer.
Ground the enclosure in accordance with nec and local electrical codes. The three lv conductors (secondaries) usually come out of the side of the transformer and feed three wires running below the hv line. They are mounted using a traditional din mount for faster installation.
Note are two bushings (x1 on the left transformer and Otherwise, intermediate poles are required. Best results will be obtained if the transformer is installed without breaking the seal, unless it is necessary to install bushings, or to repair obvious damage.
30 amps (50/60 hz or dc) voltage: The center bushing is not used on these two. 75kva and larger use t3h.
Each reman product must meet or exceed the testing standards set by ansi. There are also many poles that can not install transformers, such as poles below 8 meters high (8 meters in not included). Bury ground plate a minimum of 5 feet in undisturbed earth.
Pole mounted transformer and cutout on pole. Below those three wires you got the neutral. It is normally the middle transformer on the pole.
Aerially mounted installations may supply several buildings. They are also suitable for light commercial loads, industrial lighting and diversified power applications. Fold ends back over side of pole.
The other two transformers are the power transformers. For 200kva transformers and above, the isolating switch shall be left at the transformer pole, and separate circuit fusing using a switch fuse shall be ere cted on the adjacent pole in each direction from the transformer. A neutral is not necessary the same thing as a ground.
There are wires that run down the poles to the ground that are attached to the mgn of course which keeps the mgn at the reference voltage. The service could be wired to an exterior meter as shown here, or to service equipment inside the building. Secondary wiring should drop directly to the buildings served, if the span does not exceed 125 feet;
The lightning arresters are installed on the h.t. General electrical connection diagrams 124 acme electric u milwaukee, wi u 00.1 u acmetransformer.com general acme® transformer™ wiring diagrams primary: Sxzo design this document is also included in the following manual:
The 11 kv line is connected to the transformer (11kv / 400 v) through gang isolator and fuses. This transformer has been carefully sealed and leak tested at the factory.

Delta Primary and 4wire WYE Secondary electrikals
Wiring Schematic Of Pole Transformer Wiring Diagram Schemas

120V connection for polemounted distribution

Why is 240V called "Single Phase"? HVAC School
Wiring Schematic Of Pole Transformer Wiring Diagram Schemas
Wiring Schematic Of Pole Transformer / 3 Pole Transfer

Electrical by Jules Bartow Technology In The Vein Creepy

Basic parts of a SinglePhase PoleMounted Distribution

Inside household distribution transformer electrical

Transformer Wiring Diagram Explained How To Wire 3 Phase

utility pole diagram Electrical Engineering Books
Wiring Schematic Of Pole Transformer Wiring Diagram Schemas

Transformers for Linemen Alexander Publications

480 VAC, 3∅ Distribution Question Page 3
Fuse Box Transformer Wiring Diagram
Wiring Schematic Of Pole Transformer Wiring Diagram Schemas

Wiring Schematic Of Pole Transformer dunianarsesh